wns boiler picture

1-20 ton gas/oil fired boiler

Price: $12000-$450000/set

Capacity: 1-20 ton/h

Pressure: 0.7-2 Mpa

Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

szs boiler picture

7-70 MW gas/oil fired hot water boiler

Price: $160000-$1800000/set

Capacity: 7-70 MW

Pressure: 1.0-1.6 Mpa

Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, hospital, colleges and universities.

szl boiler picture

2.8-29mw coal fired boiler

Price: $70000-$750000/set

Capacity: 2.8-29mw

Pressure: 1.0-1.25 Mpa

Fuel: Bituminous coal, lean coal, anthracite

Industries: Heating, hotels, schools, hospitals

yyw boiler picture

horizontal thermal fluid heater

Price: $12000-$350000/set

Capacity: 700 - 14000 kw

Pressure: 0.8 - 1.0 Mpa

Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

dzl boiler picture

1-20 ton biomass fired boiler

Price: $12000-$350000/set

Capacity: 1-20 ton/h

Pressure: 0.7-2.5 Mpa

Fuel: Biomass particles

Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Steam boilers, Water vapor boilers - All

Find all the manufacturers of steam boilers and contact them directly on low- emission (4) . steam boiler model GE 1000 RV, to produce 1,000 kg/h of steam at 8 bar. steam boiler / gas / fire tube / three-pass HH series ATTSU TERMICA S.L. .. steam boilers,capacity range 500kg/h-5000kg/h working pressure 3bar- 10

Electric Steam Boiler in a Customised Industrial

TT BOILERS Electrical Heated Steam Boilers are made in an rigid industrial Best economy after 3 - 4 years; Made in own workshop in Copenhagen, Customized optional design with capacity and steam pressure above 700 kg/h - 16 bar and in special executions. Steam Boiler 250 kW for Swedish Food Industry.

TT BOILERS Steam Boilers for Process Heating

Small and medium sized 3-pass steam boilers for production of saturated steam upto 4000 kg/h and 20 barg. Steam Capacities, 80 - 4,000 kg/hour 5 bar steam pressure, 90% efficiency and normal European quality light fuel oil (Hi= 42.300 kJ/kg) and 800, 556, 52,6 · 56,2, 3390, 2320, 1520, 1320, 1840, ø250, 2,900.

Boilers - Steam - Used Process Equipment

Design pressure units 1,2 3, 1500 psig, unit 4 - 1675 psig. Max 250 psi. 127206 lbs/hr (57.7 t/hr) @ 72 barg 510 deg C, coal fired steam boiler system, . 17636 lb/hr (8000 kg/hr) @ 16 bar, steam boiler serial 45534, type Loos.

Boiler Ratings : International site for Spirax

This tutorial explains the three most commonly used boiler ratings: The From and As the boiler pressure rises, the saturation temperature is increased, Both these effects reduce the actual steam output of the boiler, for the same A boiler has a from and at rating of 2 000 kg/h and operates at 15 bar g. Example 3.5.4.

Flash Steam : International site for Spirax Sarco

As an example, when steam is taken from a boiler and the boiler pressure drops, If the equipment using steam at 7 bar g were condensing 250 kg/h, then the amount of Example 14.6.3 Consider the condensate in Example 14.6.1 discharging to a flash Example 14.6.4 demonstrates flash vessel sizing, using a chart.

Industrial boilers Planner Guide ( steam systems

3. Benefit of Hoval steam boilers. 9. 4. System PI Diagram. 10. 5. Design Basics. 12. 5.1 .. (size 500 5000 kg/h), steam pressure 10, 13, 16 bar(g) .. 1072,7. 2801,1. 1728,4. 40. 250,33. 0,050. 20,10. 1087,4. 2800,3. 1712,9. 42. 253,24.

Properties of Saturated Steam - SI Units -

A Saturated Steam Table with steam properties as specific volume, density, specific enthalpy and specific entropy. (kg/msup3/sup), Specific Enthalpy of, Specific . At 7 bar gauge (absolute 800 kN/msup2/sup) - the saturation temperature of water is 170 supo/supC. boiler shells caused by steam pressure; Sizing Steam Pipes (kg/h) - Steam is a

Sizing Steam Pipes i( kg/ h)/i - Engineering

Steam pipes can be sized with the table and diagram below - pressure in bar, velocity in m/s and capacity in kg/h. steam pipe sizing. sizing steam Pipe Size ( mm). 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 3, 15, 16, 37, 60, 93, 127, 245, 385, 535, 925, 1505, 2040, 3983, 6217, 8743. 25, 26, 56, 100, 152

properties of steam - Elements of Heat Engines

3-1. Formation of steam at constant pressure. The water will expand slightly during the . Wet Steam : The steam in the steam space of a boiler generally contains . From steam tables, at 10 bar, enthalpy of saturated water, h = 762-81 kJ/kg and Heat needed to convert 4 kg of water into steam = 4 x 2,747-47 = 10,990 kJ.

technical reference guide - Filter

There is now a continuous flow of steam from the boiler to satisfy 2 Dry saturated steam pressure/specific volume relationship. 0. 1. 2. 3. 4. 5. 6. 7. 8 .. 13. Pressure Velocity kg/h bar m/s. 15mm 20mm 25mm 32mm 40mm 50mm 65mm 80mm 250. 431. 680 1006 1708 27911. 3852. 0.7. 25. 12. 25. 45. 72. 100. 182. 287.

News - ATTSU - Steam boilers, fluid and oil

I S stamp and pressure equipment designed according to ASME sec. ATTSU exports 4 electric steam boilers of 3,4MW each to South Africa an electric steam boiler model GE 1000 RV, to produce 1,000 kg/h of steam at 8 bar. . This is a high efficiency electric steam boiler with a production of 250 kg/h that will serve

Electrical E100

Electrical E 100 steam capacity 135 / 160 kg/h. Product ready-to-operate boiler housing installation. Size. Size. Size. 80 - 120. 150 - 200. 250 - 400. 500 - 600. 700 - 850. 1000 - 1300. 1500 - 1800. 2. 3. 4. Capacities Steam kg/h. Capacities Steam kg/h. Capacities Steam kg/h permissible steam pressure (bar) . 1000.

ENERGY BALANCES OF CHEMICAL ENGINEERING -

Mar 17, 2014 659) 7.5b Steam Tables 7.5 Tables of 328 Chapter 7 Energy and Energy Balance on Water 1150 kg/h + mt = 334 Chapter 7 Energy and Energy Balances loss . column is provided by condensing saturated steam at a pressure of 15 bar. .. If 250 J of work is done to the system, what is the value of W? 3.

past_exam_ans.doc

3. One gram mole of a gas at a temperature of 25oC and a pressure of 1 bar is A rigid tank 3 m3 in total volume initially contains 1200 kg of saturated liquid 2b ) (4 pts) The initial specific volumes of saturate water and steam are: Vl . If H rxn = -200 kcal/mol = constant, Ka = 1.2 1012 at 300oK, Ka at 280oK is ______.

Engineering Thermodynamics Pages 51 - 96 - Text

Dec 10, 2014 Determine the state of the steam at exit from the turbine and the Solution: From steam tables at 6 MPa and 500°C, h 1 = 3422.2 kJ/kg, and s 1 . kg of steam are produced, determine: a) the heat supplied in the boiler. b) the The gas 3 undergoes a constant pressure process until the 0 = 250 118 2 .

CHE 31. Introduction to Chemical Engineering

3. Calculate the change of enthalpy that occurs when 5 kg of water at 70°C in a 4. Determine Q, W, U and H for the isothermal expansion of 1.31 mol of an Saturated steam at a gauge pressure of 2.0 bar is to be used to heat a Steam produced in a boiler is frequently wet that is, it is a mist composed of saturated .

Model RHP 600-750 Steam Boilers - Reimers Electra

POWER. kW. STEAM. CAPACITY lbs/hr (kg/hr). (3). BHP. VOLTAGE. (1). 50/60Hz . PHASE requirements of the A.S.M.E. Boiler and Pressure Vessel. Code and

class 25

Oct 26, 2010 input required to produce 15,000 m3/h of steam at the exiting Liquid water is fed to a boiler at 24oC and 10 bars and is converted at constant

880 Series Inverted Bucket Steam Traps

For Pressures to 250 psig (17 bar)Capacities to 4,400 lb/hr (2,000 kg/hr). C. A. B. D. E. Description. The most reliable steam trap knownthe inverted bucket provides efficient Maximum working pressure that will be encountered or orifice size 1/4. 6. 1/2. 15. 3/4. 20. A (Flange Diameter). 3-3/4. 95.2. 3-3/4. 95.2. 5-5/8 .